Fill level sensor
LCPB seriesFeatures:
- Continuous, contact-free level monitoring over wide measurement ranges
- Immune to almost any interference from the outside
- Capacitive measurement of many liquids and solids
- Small sized, easily mountable outside of container
- Accurate measurement even with air gaps between sensor and container, allowing operation e.g. with exchangeable tanks
- Various custom options available
Measuring range | see outline drawing (others on request) |
Measurement type | capaTEC® |
Permittivity of the medium | 4 < er < 82 |
Wallthickness | typ. up to 5mm*1 (e.g. glas, PE, PP, ABS, others) |
others) | |
Air gap | typ. up to 3mm*1 |
Accuracy | typ. ±2mm*1 |
Resolution | typ. 11 bit |
Response time | typ. 100 ms |
Power supply | 5V DC, max. 30mA |
Output | I2C, PWM on request*2 |
Output bus voltage | 3.3 up to 5.0V DC I2C (open-drain) |
5V DC-tolerant 3.3V DC PWM | |
(push-pull) | |
Operating temperature | -25 to +85°C |
Storage temperature | -40 to +100°C |
Humidity | max. 95% r.H., non-condensing |
Max. height over sealevel | 0 up to 2000m (others on request) |
Protection class | IP20 |
*1 Sensors measures capacitance. Accuracy of level reading is function of number of parameters including container material, wall thickness, air gaps, media and others. Typical values refer to a random water tank setting.
*2 EBE offers sensor interface boxes including software to allow PWM outputs to be set and adjusted.
Note:
Sensor output is calibrated and temperature compensated. To compensate for the application environment, an one-point calibration after mounting in the end application is generally recommended. Capacitive sensors are for use with non-metallic container material only!
capaTEC2 vs. capaTEC4:
capaTEC2 and capaTEC4 are different EBE measurement methods to determine the capacitive value (and level therefore). Both measurement methods have their specific advantages and disadvantages.
capaTEC2 measurement is generally recommended with media of a permittivity of >20 (e.g. water). For media with permittivity of less than 20, capaTEC4 may provide some advantages. EBE recommends comparing values for both capaTEC2 and capaTEC4 in the end application. This should quickly reveal the preferred method.
Electrical connection:
A 2mm (0.079") 4-pole shrouded SMT header is assembled on the sensor PCB. To avoid mechanical stress on the connector, a cable fixation shall be used to avoid damaging the sensor.
Pin | I2C | PWM*3 |
1 | VCC | VCC |
2 | SDA | PWM |
3 | SCL | n/a |
4 | Ground | Ground |
*3 EBE offers sensor interface boxes including software to allow PWM outputs to be set and adjusted.

Possible connectors (female crimp housing 4-pole) for LCPB include e.g. Molex 0510650400.
You will find further mounting instructions in the datasheet.
Manufacturer: EBE
Documents